固德威_ES系列 用户手册-EN
APP (iOS)Official Website APP (Android) ES SERIES USER MANUAL HYBRID INVERTER No.189 Kun Lun Shan Road, SND, Jiangsu, China. www.goodwe.com service@goodwe.com Jiangsu GoodWe Power Supply Technology Co.,Ltd 340-00004-03 V ersion: 1.0 INTRODUCTION 021.2 SAFETY 2. One EzMeter 3. CT must be connected on the same phase with EzMeter power cable NOTE: 1.Please use the EzMeter and CT in GoodWe product box; 2.CT cable is 3m as default, could be extended to max 5m 3.EzMeter communication cable (RJ45) is attached on the inverter (“To EzMeter” cable), could be extended to max 100m, and must use standard RJ45 cable and plug, as below: INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 13 14 2.4.4 EZMETER Password: admin Then click “OK” Step 1 Click “Start Setup” to choose your router Then click “Next” 1. Fill in the password of the router, then click “Next” 2. Click “Complete” • Wi-Fi Reset GW3648D-ES: 4050 for CEI 0-21 [7] GW5048D-ES 21.7A only for Australia and New Zealand,GW3648D-ES:18A for CEI 0-21 [8] GW5048D-ES 40A to inverter and backup, max 21.5A to inverter, GW3648D-ES:32A to inverter and backup, max 18A to inverter [9] Default communication with BMS is CAN, requirment RS485 needs special configuration process GW3648D-ES GW5048D-ES Nominal Power Output to Grid (W) AC Output Data (On-grid) Max. Apparent Power Output to Grid(VA) Max. Apparent Power From Grid(VA) Nominal Output Voltage (V) Nominal Output Frequency (Hz) Max. AC Output Current to Grid (A) [7] Max. AC Current from Grid (A) [8] Max. Output Fault Current (Peak/Duration) AC Back-feed Current (A) Output Inrush Current (Peak/Duration) Input Inrush Current (Peak/Duration) Output Power Factor Output THDi (@Nominal Output) AC Overvoltage Category Efficiency Max. Efficiency ~1(Adjustable from 0.8 leading to 0.8 Lagging) !3% 97.6% ü Max. Battery to Load Efficiency 94.0% Europe Efficiency 97.0% MPPT Efficiency 99.9% General Data Operation Temperature Range ( ¥) -25~60 Storage Temperature Range ( ¥) Relative Humidity Moisture Location Category 0~95% 4K4H External Environment Pollute Degree Grade 1,2,3 Environment Category Outdoor XA=j0,15 at 50Hz; RN=0,16;XN=j0,10 at 50Hz. For Australian requirements, in the THDi test, there should add Zref between inverter and mains. RA , XA for Line conductor RN, XN for Neutral conductor • CERTIFICATES OF ES SERIES • OTHER TEST G83 G59 G100 IEC62109-1 CEI 0-21 VDE0126-1-1 VDE-AR-N 4105 NRS 097-2-1RD1699 4.4 WARINING QUICK CHECK LIST [1] Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment, page 06 [2] Remember that this inverter is heavy! Please be careful when lifting out from the package, page 07 [3] The polarity of PV strings or on the inverter cannot be connected by reverse, otherwise inverter could be damaged, page 08 [4] Make sure battery switch is off and battery nominal voltage meet ES specification before connecting battery to inverter and make sure inverter is totally isolated from PV and AC power, page 09 [5] Make sure inverter is totally isolated from any DC or AC power before connectiong AC cable,page 11 [6] Make sure AC cable is totally isolated from AC power before connecting EzMeter and CT,page 13 Integrated (AFD)Anti-islanding Protection Protection Integrated PV String Input Polarity Reverse Protection Certifications & Standards Isolation Resistor Detection Integrated Residual Current Monitoring Unit Integrated Output Over-current Protection Integrated Output Short Protection Integrated Output Over-voltage Protection Integrated Safety Regulation IEC/EN62109-1 & -2, IEC62040-1 EMC EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-4-16, EN61000-4-18, EN61000-4-29 Grid Regulation AS/NZS 4777.2:2015, G83/2, G100, CEI 0-21, VDE-AR-N4105, VDE0126-1-1, NRS 097-2-1 AS/NZS 4777.2:2015, G59/3, G100, CEI 0-21, VDE-AR-N4105, VDE0126-1-1, NRS 097-2-1 GW3648D-ES GW5048D-ES 3680 3680 7360 230 single phase 50/60 16 32 0 43A, 0.2s 55A, 5µs 60A, 3µs 4600 5100 9200 230 single phase 50/60 24.5 40 0 43A, 0.2s 55A, 5µs 60A, 3µs Appendix: Protection Category Definition No pollution or only dry, non-conductive pollution occurs. The pollution has no influencePollution Degree ú Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Pollution Degree û Conductive pollution occurs, or dry, non-conductive pollution occurs, which becomes conductive due to condensation, which is expected. Pollution Degree ü Persistent conductive pollution occurs, for example, the pollution caused by conductive dust, rain and snow.Pollution Degree ý Pollution Degree Definition Relative Humidity Applied to -20 ~ 50 ¥ Ambient Temperature 4% ~ 100% PD3Outdoor Environment Condition Indoor Unconditioned Indoor Conditioned -20 ~ 50 ¥ 5% ~ 95% 5% ~ 85% PD3 PD20 ~ 40 ¥ Environment Category Definition Applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low levelCategory ú Applies to equipment not permanently connected to the installation. Examples are appliances, portables tools and other plug-connected equipment Category û Applies to a fixed equipment downstream of and including the main distribution board. Examples are switchgear and other equipment in an industrial installation Category ü Applies to equipment permanently connected at the origin of an installation (upstream of the main distribution board). Example are electricity meters, primary over-current protection equipment and other equipment connected directly to outdoor open lines Category ý Overvoltage Category Definition Level 3K3 4K2 4K4H Moisture Parameters Humidity Range 15%~100% Temperature Range 0~+40 ¥ -33~+40 ¥ -20~+55 ¥ 4%~100%5%~85% Moisture Location Category Definition OTHERS OTHERS 29