solarbe文库
首页 solarbe文库 > 资源分类 > PDF文档下载

1-3-Dudzak_QCprocedure

  • 资源大小:3.31MB        全文页数:21页
  • 资源格式: PDF        下载权限:游客/注册会员/VIP会员    下载费用:5金币 【人民币5元】
游客快捷下载 游客一键下载
会员登录下载
下载资源需要5金币 【人民币5元】

邮箱/手机:
温馨提示:
支付成功后,系统会根据您填写的邮箱或者手机号作为您下次登录的用户名和密码(如填写的是手机,那登陆用户名和密码就是手机号),方便下次登录下载和查询订单;
特别说明:
请自助下载,系统不会自动发送文件的哦;
支付方式: 微信支付    支付宝   
验证码:   换一换

 
友情提示
2、本站资源不支持迅雷下载,请使用浏览器直接下载(不支持QQ浏览器)
3、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰   
4、下载无积分?请看这里!
积分获取规则:
1充值vip,全站共享文档免费下;直达》》
2注册即送10积分;直达》》
3上传文档通过审核获取5积分,用户下载获取积分总额;直达》》
4邀请好友访问随机获取1-3积分;直达》》
5邀请好友注册随机获取3-5积分;直达》》
6每日打卡赠送1-10积分。直达》》

1-3-Dudzak_QCprocedure

PVPMC Salt Lake City 2022 Jozef Dudzak, Marketa Hulik Jansova, Tomas Cebecauer and Branislav Schnierer Solar ground measurements processing by automatic and manual tools Solargis approach to quality control PVPMC Salt Lake City 2022 Agenda ● Why ground measurements ● Solargis quality assessment procedure PVPMC Salt Lake City 2022 Why ground measurements * In case of poor maintenance * PVPMC Salt Lake City 2022 Why ground measurements ● High quality measurements can be used for improvement of the accuracy of models by site adaptation ● Reduced uncertainty of site adapted satellite data provides better conditions for project financing Usage of ground measurements ● Improvement of satellite-based model ● Improvement of forecast accuracy ● PV performance evaluation ● Identification of PV operation issues PVPMC Salt Lake City 2022 About ground measurements ● Current status our experience ○ Missing knowledge of proper operation ○ Suboptimal practices ○ Solar and meteo measurements are often degraded ● Best practices ○ More than one instruments to be installed on a site if feasible ○ Choice of instruments optimal ■ Class A pyranometers GHI1, GHI2, DIF ventilation unit ■ Class A pyrheliometers DNI ■ Class A albedometer RHI, GHI ○ Fine temporal resolution of data 1min, 5 min ○ Regular cleaning, maintenance and calibration of instruments by trained personnel ○ Data quality control by a knowledgeable expert PVPMC Salt Lake City 2022 About ground measurements Length of measurement campaign for model site adaptation ● Less than 12 months - Preliminary model data verification only ● 12 months - Validation and site-adaptation of satellite-based model ● 24 months - More robust validation site-adaptation with lower uncertainty PVPMC Salt Lake City 2022 What to do to have high quality ground measurements ● Good station operation ○ Obey best practices ○ Professional installation ○ Accurate characteristics of data coordinates, calibrated and described instruments, cleaning and maintenance logs ○ Professional operation and maintenance ● Precise QC ○ Time reference harmonization ○ Physical outliers ○ Detection of instrument location specific issues logger issue, tracking issue, dew/frost, shading, . PVPMC Salt Lake City 2022 Is quality control important Definitely YES Our internal analysis has shown that, on average, 13 of GHI and DIF measurements are affected by errors during the station operation. 15 of GTI measurements and 23 of DNI measurements were also affected by errors. Analysis was performed on projects from last 4 years. PVPMC Salt Lake City 2022 Solargis quality assessment procedure ● Step 1 Time reference control ● Step 2 Basic numerical check of physical limits ● Step 3 Extended numerical identification of systematic data errors ● Step 4 Manual quality control All quality control steps and tools for data handling are fully integrated into the Solargis Analyst. PVPMC Salt Lake City 2022 Time reference control ● Issue description ○ Time in UTC - determines the solar position calculation ○ Basic prerequisite for data quality tests○ Typical issues ■ Shift with respect to UTC■ Daylight saving time ■ Random shifts and drifts■ Timestamp definition left, right, center ● Automatic detection based on ○ Symmetry of profile between morning and afternoon ○ Alignment with the reference ● Limitations ○ Wrong coordinates○ Mix with other issues ○ Shifts during day PVPMC Salt Lake City 2022 Instrument misalignment and GTI configuration ● Issue description ○ Pyranometer for measuring GHI not placed horizontally ○ Fixed tilted pyranometer azimuth and tilt not given or given properly ● Automatic detection based on ○ Similarity of misaligned profiles ● Limitations ○ For now we can only estimate fixed mounting GTI parameters Photo Iberdrola https//www.kintech-engineering.com/wp-content/uploads/2018/07/Case_Study_09.pdf PVPMC Salt Lake City 2022 Physical limits and large outliers ● Issue description ○ Data Logger problems and other issues can drive the measurements to unphysical values ○ There are consistency rules between 2 or 3 radiation components ● Automatic detection based on ○ Methods defined in BSRN procedures and methods implemented in-house by Solargis ● Limitations ○ In case of inconsistency we are not able to say which component is affected ○ Many issues are still in the range of physical values PVPMC Salt Lake City 2022 Shading detection ● Issue description ○ Shading of instruments by horizon or nearby objects ○ Global, direct and reflected irradiation are affected. ● Automatic detection based on ○ Systematic decrease of measured irradiation values ● Limitations ○ Disappearing/appearing shading ○ Half-transparent objects PVPMC Salt Lake City 2022 Tracker malfunction ● Issue description ○ Pyrheliometer DNI is not tracking sun properly ● Automatic detection based on ○ Zero or low DNI values during cloudless conditions ○ Inconsistent information compared to other components of solar radiation ● Limitations ○ Partial tracking malfunction slight misalignment of the pyrheliometer PVPMC Salt Lake City 2022 Dew/frost detection ● Issue description ○ Deterioration of the measurement due to dew or frost on the instrument ● Automatic detection based on ○ Specific “S” shape of the measurement during this event ● Limitations ○ Only available for pyranometers with glassdome Source DOI - 10.13140/RG.2.1.1515.6568 PVPMC Salt Lake City 2022 Signal degradation ● Issue description ○ Systematic degradation of signal due to soiling or calibration issues ○ More accurate detection when all three solar radiation components are available ● Automatic detection based on ○ Systematic decrease of signal in time period ● Limitations ○ Soiling does not always cause systematic degradation of signal ○ We need to work with longer time periods at least 14 days PVPMC Salt Lake City 2022 Manual assessment ● Description ○ Assessment and flagging by skilled operator rare, random, convoluted or smaller issues ○ Identification of less frequent issues artificial noise, station grounding issue ○ Control of residual issues after automatic tools ○ Control of site specific conditions and issues ○ Final approval of data quality for further processing ● Requirements ○ Well trained operator required ○ Reliable software tool for analysis of solar data ○ Site and instruments specification ○ Good installation and operation of measurement station ○ The most time consuming part of QC PVPMC Salt Lake City 2022 How to avoid these issues in your data ● Consider the frequency of cleaning events regarding to climate dust deposition region. ● Store detailed information about each maintenance and cleaning event. ● It is recommended to perform instrument cleaning during the daytime. It allows identifying the soiling of the instrument. ● Check the installation and alignment of instruments during every maintenance cleaning event ● Instal ventilation and heating units on instruments ● Instal instrument on the position without shading, reflection or another artificial effects on measurements eg. albedometer above representative ground coverage ● Use UTC without daylight-saving time PVPMC Salt Lake City 2022 Summary Why we went through this procedure ● We need high quality data to be able to further process them and rely on them ● Usage of flagged data ○ Perform model site adaptation and reduce uncertainty ○ Perform gap filling and create consistent dataset of multiple years ○ Perform PV performance analysis - KPI calculations ○ Improve forecasts ○ Improve satellite-based model public sites PVPMC Salt Lake City 2022 Conclusion Ground measurements are important record of local climate, but ● High quality measurements require attention ○ Station installation ○ Instruments maintenance ○ Data quality control Data quality control is time-consuming work but necessary to achieve the highest data quality. Solargis Analyst ● Helps not only with quality control but also with data management, visualisation and analysis of ground measurements ● Includes analytical tools for solar resource assessment ● Development of new features to support the industry ● More info solargis.com/products/analyst PVPMC Salt Lake City 2022 Jozef Dudzak, Marketa Hulik Jansova, Tomas Cebecauer and Branislav Schnierer Solar ground measurements processing by automatic and manual tools Solargis approach to quality control

注意事项

本文(1-3-Dudzak_QCprocedure)为本站会员(小光伏)主动上传,solarbe文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知solarbe文库(发送邮件至401608886@qq.com或直接QQ联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。

copyright@ 2008-2013 solarbe文库网站版权所有
经营许可证编号:京ICP备10028102号-1

公众号二维码
收起
展开