solarbe文库
首页 solarbe文库 > 资源分类 > PDF文档下载

双面组件跟踪系统的技术经济性表现-cell press -joule

  • 资源大小:8.51MB        全文页数:29页
  • 资源格式: PDF        下载权限:游客/注册会员/VIP会员    下载费用:5金币 【人民币5元】
游客快捷下载 游客一键下载
会员登录下载
下载资源需要5金币 【人民币5元】

邮箱/手机:
温馨提示:
支付成功后,系统会根据您填写的邮箱或者手机号作为您下次登录的用户名和密码(如填写的是手机,那登陆用户名和密码就是手机号),方便下次登录下载和查询订单;
特别说明:
请自助下载,系统不会自动发送文件的哦;
支付方式: 微信支付    支付宝   
验证码:   换一换

 
友情提示
2、本站资源不支持迅雷下载,请使用浏览器直接下载(不支持QQ浏览器)
3、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰   
4、下载无积分?请看这里!
积分获取规则:
1充值vip,全站共享文档免费下;直达》》
2注册即送10积分;直达》》
3上传文档通过审核获取5积分,用户下载获取积分总额;直达》》
4邀请好友访问随机获取1-3积分;直达》》
5邀请好友注册随机获取3-5积分;直达》》
6每日打卡赠送1-10积分。直达》》

双面组件跟踪系统的技术经济性表现-cell press -joule

Article Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Systems This work performs a comprehensive techno-economic analysis worldwide for photovoltaic systems using a combination of bifacial modules and single- and dual-axis trackers. We find that single-axis trackers with bifacial modules achieve the lowest LCOE in the majority of locations 16 reduction on average. Yield is Carlos D. Rodrıguez-Gallegos, Haohui Liu, Oktoviano Gandhi,.,LiLi,ThomasReindl, Ian Marius Peters carlos.rodrigueznus.edu.sg HIGHLIGHTS Techno-economic comparison of combinations of bifacial and tracking PV systems Worldwide assessment of yield and LCOE Bifacial modules with single-axis trackers achieve lowest LCOE in most locations Bifacial modules with single- and dual-axis trackers boost yield by 35 and 40 ll Rodrıguez-Gallegos et al., Joule 4,1–28 July 15, 2020 2020 Elsevier Inc. https//doi.org/10.1016/j.joule.2020.05.005 boosted by 35 by using bifacial modules with single-axis trackers and by 40 in combination with dual-axis trackers. Systems 1 Jai Prakash Singh, 1 3 Li Li, 4 Thomas Reindl, 1 ance reaching both the front and rear surfaces of the modules for the different system designs validated based on data from real most commonly installed new generation source. 2 The majority of current PV in- stallations employ monofacial crystalline silicon PV modules 3,4 with a fixed-tilt sys- Context i.e.,willthesesystemshavealowerLCOEthanstandardmonofacialfixed- tilt installations Hence, in this paper, we explore the cost effectivenessof monofacialand bifacialPV farms with fixed-tilt, 1T and 2T installations worldwide. A sketch of the analyzed mounting structures is presented in Figure 1, also indicating the irradiance reaching both the front and rear sides. As the first step, we developed a performance model for the different mounting approaches using satellite data Methodology. We cali- brated this model against field-measured data from fixed-tilt and tracking installa- tions and showed agreement with an overall deviation below 3 Validation of Irra- diance Calculation Methodology. We then extended this study globally, based on the parameters provided in Global Techno-Economic Performance Calculation, andinvestigatedthetechnicalandeconomicperformanceofthedifferentmounting configurations Results. Finally, we explored the sensitivity of LCOE in a variety of locationsusingaMonteCarloandregionsensitivityapproachResults.Thisanalysis shows what changes in LCOE should be expected for variations related to weather, module, and cost parameters. A general discussion on the previous results is pre- sented in Discussion, and the paper is concluded in Conclusions. Methodology Calculation of Global/Diffuse Horizontal and Direct Normal Irradiance Daily average onevalue perdayglobal horizontal irradiance GHIisobtained from NASA’s Clouds and the Earth’s Radiant Energy System CERES. 32 Due to the influ- enceofthesun’spositionontheoverallirradiancecollectedatthemodulesurface,it is necessary to estimate the irradiance values with a higher resolution. This is ll achieved by employing an approach similar to the one presented in Sun et al. 29 The hourly GHI is first estimated by applying the clear sky model proposed by Haur- witz. 33,34 Inanefforttoreduceestimationerrors,thehourlyGHIvaluesaremultiplied by a constant so that their average is equal to the daily average GHI provided by Erlangen-Nurnberg for Renewable Energy, 91058 Erlangen, Germany 7 Lead Contact *Correspondence carlos.rodrigueznus.edu.sg https//doi.org/10.1016/j.joule.2020.05.005 2 Joule 4, 1–28, July 15, 2020 Table 1. Literature Review on the Energy Gain of Different Designs Location Module Elevation m/ Number of Modules Forming the System Albedo/Bifaciality Tilt C14 /Facing G Comments Amsterdam, The Netherlands a,10 0.5/1 0.20.5/0.923 90/east 10.429.5 monofacial module optimum tilt angle/south Doha, Qatar a,10 0.5/1 0.20.5/0.923 90/east C05.617.2 Amsterdam, The Netherlands a,11 /7 rows 0.3/0.8 optimum orientation for fixed-tilt systems 5 and 6 and 10 and 4 and 8 and 12 and 10 and 5 and 5 and 25 N/A Davis, USA b,22 2.5/3 rows 0.16/0.75 N/A 5 bifacial-1T versus monofacial-1T La Higuera, Chile b,23 2/575kWp desert sand/0.85 N/A 12.8 bifacial-1T versus monofacial-1T San Felipe, Chile a,24 0.5/72 0.120.7/0.85 30/north 734 N/A South Korea b,25 1/6 0.0621/0.82 30/south 5.2514.47 N/A Hokkaido, Japan b,26 1.5/12 grass/0.959 35/south 8.6 N/A 1.5/12 snow/0.959 35/south 23.0 N/A 1.5/12 scallops’shells/0.959 35/south 23.3 N/A N/A 1.5/12 snow/0.959 35/south 23.8 N/A Kasese, Uganda a,15 /1 0.20.5/ / 16.4743.77 N/A /1 0.20.5/ / 14.7117.93 monofacial-1T versus monofacial fixed-tilt /1 0.20.5/ / 1.5321.93 bifacial fixed-tilt versus monofacial-1T /1 0.20.5/ / 40.162.2 bifacial-1T versus monofacial fixed-tilt Unless otherwise indicated in the column ‘‘Comments,’’ G gain corresponds to the extra energy produced from a bifacial-fixed design with respect to its mono- facialcounterpart,both atthesameorientation indicatedinthecolumn‘‘Tilt C14 /facing’’.Thesymbol‘‘’’isappliedwhenthedataofinterestwerenotprovided in the literature. a Results obtained from simulations. b Results obtained from real systems. 4 Joule 4, 1–28, July 15, 2020 ll Please cite this article in press as Rodrıguez-Gallegos et al., Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Sys- tems, Joule 2020, https//doi.org/10.1016/j.joule.2020.05.005 Article model 38 and anisotropic model 5 when calculating I f and I r , respectively contribu- tions, together with the reflection losses. 39,40 Once I f and I r areobtained,thepower production of a PV system can be defined as P PV P PV;f I f I r bf 1 1000 1 gT c C025C138h inv 1C0b 0 C0yb 1 1C0l Equation 1 whereP PV;f [W p ]isthe overallpowerproductionof the installedmodulesunderstan- dard test conditions STC whenlight only reaches the module front side,b []is the bifaciality factor equal to zero when dealing with monofacial modules, and f 1 rep- resents the solar spectral distribution influence. 41,42 The temperature influence on the module performance is represented by the second term from Equation 1,where g[/ C14 C]isthepowertemperaturecoefficientandT c [ C14 C]isthecelltemperature. 43,44 Thevariableh inv []representstheinverteraverageweightedefficiency.Inaddition, b 0 [] is the initial PV degradation, while b 1 [/year] is the yearly degradation rate where y is the analyzed year. 45–47 The other losses presented in a PV installation e.g., shading, ohmic wiring losses, module mismatch, etc. are combined and rep- resented by the l [] parameter. Figure 1. Sketch on the Analyzed Mounting Structures A Fixed-tilt. B Horizontal single axis tracker HSAT. C Tilted single axis tracker TSAT. D Dual-axis tracker. Joule 4, 1–28, July 15, 2020 5 Please cite this article in press as Rodrıguez-Gallegos et al., Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Sys- tems, Joule 2020, https//doi.org/10.1016/j.joule.2020.05.005 Article WithEquation1,theoverallenergyproducedbyaPVsystemduringaparticularyear y,E y PV [Wh],canthenbecalculated.Adetailedexplanationonthepowerandenergy estimation can be found in Rodrıguez-Gallegos et al. 30 Estimation of the System Cost The overall cost for the PV system during its lifetime l S isdefinedas C PV C Bank;int C Bank;amor C own C war C insu C OM Equation 2 wheretheinitialinvestmentcost,whichincludesthecostrelatedtotheacquisitionof solar panels and inverters as well as their installation cost factor c ins , is divided into the first three terms cost of bank interest C Bank;int , cost of bank amortization C Bank;amor , and cost of ownership C own . To cover for the initial investment of a PV farm, it is usual to obtain a bank loan to pay for part of this investment resulting in the bank interest and amortization costs, while the owner of the PV farm is ex- pectedtopayfortherestresultinginthecostofownership.Inaddition,theinverter warranty cost C war is incurred every few years, while insurance cost C insu andop- erations and maintenance Oint , C Bank;amor , C war , C insu ,andC OM . Further details of each of thetermscanbefoundinRodrıguez-Gallegos et al. 30 Estimation of LCOE TheLCOE[USD cents/kWh],is taken asthe parameter toevaluatethecost effective- ness of the analyzed PV installations. This is defined as LCOE C PV P l S y 1 E y PV 1DR y Equation 3 The numerator of Equation 3 is the total cost, whereas the denominator is the energy generated by the PV system throughout its lifetime. Notice that the cost aspect of the yearly energy generation is also influenced by the discount rate, DR []. 48 Limitations of the Presented Approach There are several technical and economic aspects that are beyond the scope of this study. These include No consideration of module row-row shading and therefore, no backtracking algorithm is applied; we have assumed that the module rows were properly spaced so that these shading losses were marginal. In addition, potential shading due to the mounting structure which includes the torque tube for trackers and uneven irradiance at the module rear side are neglected. The influence that the row-row spacing has on other cost factors, such as site preparation works, wiring, fencing, etc., has also been neglected in this work. We do not consider governmental policies;thesecanhaveabiginfluenceontheLCOEandtherefore,determinewhether itiscosteffectivetoinstallaPVsysteminaparticularlocation.Wedonotconsidersoil- ing losses in detail; soiling losses are assumed to be a part of the loss parameter l and anydependenceonlocationormoduletiltangleisnotconsidered.Wedonotconsider transportation costs, which are expected to have a particular influence for locations with difficult access, e.g., deserts. We also do not consider the land cost. ll Most of these limitations affect the different considered system architectures in a similar way and should not affect our conclusions or performance rankings severely. If the land cost becomes significant, then the LCOE improvement from bifacial and 6 Joule 4, 1–28, July 15, 2020 ll Please cite this article in press as Rodrıguez-Gallegos et al., Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Sys- tems, Joule 2020, https//doi.org/10.1016/j.joule.2020.05.005 tracking technologies are expected to be diminished, as these technologies are likely to have a higher space requirement than the fixed-tilt ones. Validation of Irradiance Calculation Methodology Model validation is performed by simulating front and rear irradiance against measured values from experimental setups provided by three institutes. The measured irradiance values presented in this section were obtained from high qual- itysensors,whichhaveanon-linearityaccuracybelow0.3,e.g.,pyranometersKipp and Zonen SMP10, SMP11, and CMP11. The first analyzed data set was provided by Sandia National Laboratories and covered a time range from 17 September 2017–21 November 2017, 30 March 2018–2 May 2018, and 1 January 2019 – 9 March 2020 with a 1-min resolution for the following PV installations 1 Fixed-tiltPVsystemwithtiltangleof35 C14 facingtheequator,row-to-rowpitch of4.9m,collectorwidthof2m,lengthoftherowsof21mandheightofmod- ule lower edge of 1.1 m. 2 Horizontal single-axis tracker system HSAT with east-west rotation composed of two tracker rows referred as HSAT 1 and HSAT 2, row-to-row pitch of 6.1 m, collector width of 2 m, length of the rows of 25 m and tracker axis height of 1.7 m. These PV installations are located at Albuquerque, USA latitude of 35.05 C14 ,longi- tude of C0106.54 C14 and elevation of 1,657 m. The data provided by Sandia National Laboratories include GHI, DNI, DHI, module orientation over time, height of rear irradiance sensors, and albedo. In addition, the sun position is estimated using the SPA algorithm introduced in Calculation of Global/Diffuse Horizontal and Direct Normal Irradiance. These data are then applied to compute the irradiance reaching thefrontandrearsidesofthemodulesforthesePVinstallations.Theresultsarethen compared with the measured irradiance falling on either module plane. Figure 2 shows the time series of the simulated and measured irradiance for three selected days with specific weather conditions sunny, partly cloudy, and cloudy. Fig- ure3showstherelationbetweenthemeasuredandsimulatedirradiancevaluesforthe entire period considered. In general, we find decent agreement between measure- ment and simulation. A larger discrepancy occurs at the module rear side with a normalized root-mean-square error NRSME of approx. 5–6. The rear irradiance onlycontributesasmallfractionofthetotalirradiance.Hence,wefindsimilarNRMSEs of approx. 2–3 for both front and front rear. Figure 3 also provides the overall relative difference between the measured and simulated overall insolation I d . In addition to validating the bifacial irradiance calculation model, the accuracy of long-term irradiance calculation using satellite data following the approach from Calculation of Global/Diffuse Horizontal and Direct Normal Irradianceisalsovali- datedagainstfieldmeasurements.Here,weusedfieldmeasurementresultscollected by Harbin Institute of Technology HIT with a testbed located at Weihai, China lati- tude of 37.53 C14 , longitude of 122.08 C14 , and elevation of 10 m. More than one year of irradiance data are used. The following describe their analyzed PV systems Article 1 Fixed-tiltPVsystemwithtiltangleof34 C14 facingtheequator,row-to-rowpitch of 10 m, collector width of 2 m, length of the rows of 36 m and height of mod- ule lower edge of 0.3 m. Only front side irradiance is recorded. Joule 4, 1–28, July 15, 2020 7 Please cite this article in press as Rodrıguez-Gallegos et al., Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Sys- tems, Joule 2020, https//doi.org/10.1016/j.joule.2020.05.005 Article ll 2 Tilted single-axis tracker system TSAT with 20 C14 tilt and east-west rotation, row-to-row pitch of 5.6 m, collector width of 1.7 m, length of the rows of 31 m and tracker axis height of 2.4 m. Front and rear side irradiance are re- corded. 3 HSAT with east-west rotation, row-to-row pitch of 9.2 m, collector width of 2 m,lengthoftherowsof47mandheightofthetrackeraxisof2.2m.Onlyfront side irradiance is recorded. The monthly front and rear insolation received by the tracker systems is compared against the front side insolation of the fixed-tilt system by calculating the following ratios 1 TSAT fr /fixed f Ratio between combined front and rear insolations collected bytheTSATsystemwithrespecttothefrontinsolationofthefixed-tiltsystem. 2 HSAT f /fixed f Ratio between front insolation collected by

注意事项

本文(双面组件跟踪系统的技术经济性表现-cell press -joule)为本站会员(光伏小萝莉)主动上传,solarbe文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知solarbe文库(发送邮件至401608886@qq.com或直接QQ联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。

copyright@ 2008-2013 solarbe文库网站版权所有
经营许可证编号:京ICP备10028102号-1

1
收起
展开