solarbe文库
首页 solarbe文库 > 资源分类 > PDF文档下载

【PVPMC】Toyota-Kenji-车顶光伏性能建模综述

  • 资源大小:3.38MB        全文页数:26页
  • 资源格式: PDF        下载权限:游客/注册会员/VIP会员    下载费用:5金币 【人民币5元】
游客快捷下载 游客一键下载
会员登录下载
下载资源需要5金币 【人民币5元】

邮箱/手机:
温馨提示:
支付成功后,系统会根据您填写的邮箱或者手机号作为您下次登录的用户名和密码(如填写的是手机,那登陆用户名和密码就是手机号),方便下次登录下载和查询订单;
特别说明:
请自助下载,系统不会自动发送文件的哦;
支付方式: 微信支付    支付宝   
验证码:   换一换

 
友情提示
2、本站资源不支持迅雷下载,请使用浏览器直接下载(不支持QQ浏览器)
3、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰   
4、下载无积分?请看这里!
积分获取规则:
1充值vip,全站共享文档免费下;直达》》
2注册即送10积分;直达》》
3上传文档通过审核获取5积分,用户下载获取积分总额;直达》》
4邀请好友访问随机获取1-3积分;直达》》
5邀请好友注册随机获取3-5积分;直达》》
6每日打卡赠送1-10积分。直达》》

【PVPMC】Toyota-Kenji-车顶光伏性能建模综述

pPerformance Modeling of the Car-roof PV - OverviewKenji Araki1, Yasuyuki Ota2, and Masafumi Yamaguchi11Toyota Technological Institute, cpvkenjiarakitoyota-ti.ac.jp, Nagoya, Japan2University of Miyazaki, Miyazaki, Japan Testing car-roof PV Three issues Accurate performance measurement in indoor STC Mauro PRAVETTONI et al., SNEC 2019 Scientific ConferenceAccurate product testing STC/SOC Fair modeling in energy yield on the car Durability and safety Scientific contents in today’s presentationTesting a curved PV moduleDevelopment a protocol for repeatable measurementModeling solar irradiance on the car-roofDynamic installationShading influencePartial shading Curved PV is often overestimated. Example of the radius of curvature of the car-roof Reference Accurate performance measurement in indoor STC, Mauro PRAVETTONI et al., SNEC 2019 Scientific ConferencedFor typical solar simulators, the range of the working distance d may be a bigger issue. Curved PV is illuminated in testing out of the aperture areaPin A  Irr Pin Input energyA Aperture areaIrr IrradianceRay outside the aperture illuminates the curved PV, and input energy will be underestimated.  Overestimation of performance The virtual position of the aperture may be the geometrical gravity of the curve profile. Inconsistency in “area”, projected area vs. total areaFlattened module testedCurvedTotal area area used for testProjected area area for module operation Local cosine loss and self-shading loss are inherent, but enhanced in the outdoor operationThis means testing angular performance is essential to curved PV car-roof PV.Illumination direction in testing Illumination direction in operation Typical illumination of the curved PV in outdoor operation Curve correction factor f1 is the coving factor, or in another way, geometrical curve correction factor corresponding to the ratio of the projected area by surface area, f2 is the irradiance ratio due to the local cosine loss and self-shading loss, in other words, optical curve correction factor. f 3 is the correction of uneven expansion of the curved module. Round-robin of the car-roof PVScope Standard measurement method for the curved car-roof PV panel.PurposeIdentification of the measurement errors in measurement.Improvement of the measurement method by testing labs.PlanOperated by IEC TC82. To be started in April, 2020.We are about to investigate preliminary protocols using flexible Si modules by JET and AIST. https//www.kurumaerabi.com/car_mag/list/6690/ Minimum requirement of the solar simulator 1.0 1.1 1.2 1.3 1.4 1.5Ratio of the width/depth of the uniform illumination area relative to the procected width/depth of the curved PV panel010 203040Angle of divergence deg 2 5 10Contor of the max-min/mean of flux illuminating onto the curved panel BackgroundThe minimum requirement of the solar simulator standard type shown in the last meeting was too strict for testing laboratory equipped with instruments to normal PV modules.RelaxationFlux not irradiance onto the of Si cell region is less than 1 after correction of illumination level at the plane of the center of gravity of the surface.Illuminated Area 10 more module lengthAND Angle of divergence 30 Ultimate solution Collimated solar simulator For more information, visit http//solaraddedvalue.com/en/category/productos/helios-3198/ Mathematical solution by Dr. Tayagaki, AIST The curve correction factor may be approximated byT Tayagaki, K Araki, M Yamaguchi, T Sugaya, IEEE Journal of Photovoltaics 9 6, 1721-1726 Solar irradiation of the car-roof is complicated but can be modeled. Solar resource monitoring around the car-body by University of Miyazaki Why is 5-axis measurement important “One sensor on the car-roof” does not have sufficient DOF to validate the outdoor irradiance model. 3-D evaluation including angular weighting is crucial to the module design. Shading effect locally varies, for example, less shading in y direction than x direction. One sensor monitoring cannot detect such car-specific solar environment. Car-roof PV modelingReference Car-roof Coving factor 0.97Equivalent R 3.5 m Validation of the model - IntensityAnnually MonthlyDaily Validation of the model – Angular distribution 012345678 0 15 30 45 60 75 90Weighted percentage Incident angle deg ModelMeasurement Note Validation was done by the weighted histogram of the incident angle of the main beam. Inherent error is expected to the higher incident angle corresponding overcast conditions incident angle of the main beam becomes indetermination. Not only geometrical parameter 1Curve correction factor is affected by the angular distribution of the irradiation, thus varies by place. Not only geometrical parameter 2Uneven distribution of the solar irradiance due to curved surface, dynamic shading and partial shading Significant mismatching lossUnpredictable and complicated by string and variation of shape designsCombination of Graph theory and Monte Carlo simulation is investigated Design recommendation by the knowledge in the solar modeling. Relative to GHI, incl. curve-correction Rough estimation 1/3Power marginDepending on the driving zones latitude, climates, 20 power margin is recommended by the reduction of the effective irradiance on the car-roof. Rough estimation 2/3Urban drivingPartial shading probability mismatching loss substantially increases in the urban driving. Use of the cut cells thus increasing string number is inevitable. 1/2 cut, 4 strings 1/8 cut, 16 strings1/4 cut, 8 strings Rough estimation 3/3Partial shadings1/6 or more cut is recommended for suppressing partial-shading loss to 10. Let39;s study togetherAs resources increase, substantial greenhouse gas reduction will be achieved quickly.20 years ahead → 10 years ahead → 5 years aheadAcknowledgement A part of this research is based on NEDO entrusted research “research and development of ultrahigh efficiency low cost III-V compound solar cell module“. I thank the people concerned.For this proposal, we received a hot discussions at various conferences. I am thankful to CPV guys and PV masters of high spirit.Regarding in-vehicle PV and peripheral technologies, I repeatedly discussed with Toyota Motor Corporation, Miyazaki University and Nagaoka University of Technology. Again thank you once again, next time I will delicious delicacies in Nagoya. 26/p

注意事项

本文(【PVPMC】Toyota-Kenji-车顶光伏性能建模综述)为本站会员(光伏小萝莉)主动上传,solarbe文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知solarbe文库(发送邮件至401608886@qq.com或直接QQ联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。

copyright@ 2008-2013 solarbe文库网站版权所有
经营许可证编号:京ICP备10028102号-1

1
收起
展开